Repositorio Dspace

Optimization of a colorectal cancer screening program through the implementation of a failure mode and effects analysis

Mostrar el registro sencillo del ítem

dc.contributor.author Martínez-Burgos, María
dc.contributor.author Villena-Salinas, Javier
dc.contributor.author Moran-Sánchez, Senador
dc.contributor.author Martínez-Otón, José-Antonio
dc.date.accessioned 2026-03-31T11:04:33Z
dc.date.available 2026-03-31T11:04:33Z
dc.date.issued 2025
dc.identifier.citation Martínez Burgos M, Villena-Salinas J, Morán Sánchez S, Martínez Otón JA. Optimization of a colorectal cancer screening program through the implementation of a failure modes and effects analysis. Rev Esp Enferm Dig. 2025. doi:10.17235/reed.2025.10646/2024
dc.identifier.issn 1130-0108
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/25624
dc.description.abstract INTRODUCTION: colorectal cancer (CRC) screening is a strategy aimed at the early detection and treatment of this condition. Inviting asymptomatic individuals to participate in the program offers potential health benefits but also exposes them to possible complications associated with the process. MATERIAL AND METHODS: a single-center, descriptive risk management study was performed using the failure modes and effects analysis (FMEA) methodology. In the first phase, failure modes were identified through brainstorming sessions involving all relevant personnel. These were then categorized based on their risk priority number (RPN), and a risk matrix was used to prioritize corrective and preventive measures for high-risk errors. Finally, interventions targeting the identified failure modes were implemented, and their impact was monitored at six months. RESULTS: a total of 12 failure modes were identified, four of which were classified as high-risk (RPN > 15). The proposed interventions were applied to mitigate these failure modes, resulting in a significant reduction in RPN scores. CONCLUSION: the application of the FMEA methodology enabled the identification of high-risk errors in the CRC screening process and the implementation of measures to mitigate them, leading to improvements in the safety and quality of the program.
dc.language.iso spa
dc.publisher ARAN EDICIONES, S A
dc.rights Atribución/Reconocimiento 4.0 Internacional 
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es  *
dc.subject.mesh Humans
dc.subject.mesh Colorectal Neoplasms/diagnosis
dc.subject.mesh Early Detection of Cancer/standards/methods
dc.subject.mesh Healthcare Failure Mode and Effect Analysis
dc.subject.mesh Mass Screening/standards
dc.title Optimization of a colorectal cancer screening program through the implementation of a failure mode and effects analysis
dc.type info:eu-repo/semantics/article 
dc.identifier.pmid 40575916
dc.relation.publisherversion https://online.reed.es/fichaArticulo.aspx?iarf=456568182645999-765837224686760
dc.type.version info:eu-repo/semantics/publishedVersion 
dc.identifier.doi 10.17235/reed.2025.10646/2024
dc.journal.title Revista española de enfermedades digestivas
dc.identifier.essn 2340-4167


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento 4.0 Internacional  Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento 4.0 Internacional 

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta