Repositorio Dspace

Usefulness and Limitations of Multiple Ligation-Dependent Probe Amplification in Antithrombin Deficiency

Mostrar el registro sencillo del ítem

dc.contributor.author Cifuentes, Rosa
dc.contributor.author Padilla, José
dc.contributor.author Eugenia-de-la-Morena-Barrio, María
dc.contributor.author de-la-Morena-Barrio, Belén
dc.contributor.author Bravo-Pérez, Carlos
dc.contributor.author Garrido-Rodríguez, Pedro
dc.contributor.author Llamas, María
dc.contributor.author Minano, Antonia
dc.contributor.author Vicente, Vicente
dc.contributor.author Lozano, María-Luisa
dc.contributor.author Corral, Javier
dc.date.accessioned 2025-11-24T15:17:19Z
dc.date.available 2025-11-24T15:17:19Z
dc.date.issued 2023-03
dc.identifier.citation Cifuentes R, Padilla J, De La Morena-Barrio ME, De La Morena-Barrio B, Bravo-Pérez C, Garrido-Rodríguez P, et al. Usefulness and Limitations of Multiple Ligation-Dependent Probe Amplification in Antithrombin Deficiency. IJMS. 6 de marzo de 2023;24(5):5023.
dc.identifier.issn 1661-6596
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/22430
dc.description.abstract Multiplex ligation-dependent probe amplification (MLPA) identifies genetic structural variants in SERPINC1 in 5% of cases with antithrombin deficiency (ATD), the most severe congenital thrombophilia. Our aim was to unravel the utility and limitations of MLPA in a large cohort of unrelated patients with ATD (N = 341). MLPA identified 22 structural variants (SVs) causing ATD (6.5%). MLPA did not detect SVs affecting introns (four cases), and the diagnosis was inaccurate in two cases according to long-range PCR or nanopore sequencing. MLPA was used to detect possible hidden SVs in 61 cases with type I deficiency with single nucleotide variations (SNVs) or small insertion/deletion (INDEL). One case had a false deletion of exon 7, as the 29-bp deletion affected an MLPA probe. We evaluated 32 variants affecting MLPA probes: 27 SNVs and 5 small INDELs. In three cases, MLPA gave false-positive results, all diagnosed as deletions of the affected exon: a small INDEL complex, and two SNVs affecting MLPA probes. Our study confirms the utility of MLPA to detect SVs in ATD, but also shows some limitations in detecting intronic SVs. MLPA renders imprecise and false-positive results for genetic defects which affect MLPA probes. Our results encourage the validation of MLPA results.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional 
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/es/  *
dc.subject.mesh Humans
dc.subject.mesh Thrombophilia/genetics
dc.subject.mesh Exons
dc.subject.mesh Multiplex Polymerase Chain Reaction/methods
dc.subject.mesh Introns
dc.subject.mesh Nucleotides
dc.subject.mesh Antithrombins
dc.title Usefulness and Limitations of Multiple Ligation-Dependent Probe Amplification in Antithrombin Deficiency
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 36902454
dc.relation.publisherversion https://www.mdpi.com/1422-0067/24/5/5023
dc.identifier.doi 10.3390/ijms22052777
dc.journal.title International Journal of Molecular Sciences
dc.identifier.essn 1422-0067


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional  Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional 

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta