Repositorio Dspace

Enhancing diagnostic precision: a multicentric study of endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy in lymphoproliferative disorders

Mostrar el registro sencillo del ítem

dc.contributor.author Ariza-Prota, Miguel; Perez-Pallares, Javier; Barisione, Emanuela; Cruz-Rueda, Juan Jose; Onyancha, Sammy; Usturoi, Daniela; De Santis, Michele; Salcedo-Lobera, Esperanza; Ferrer-Pargada, Diego; Corcione, Nadia; Caballero-Vazquez, Alberto; Rodriguez-Blanco, Ignacio; Torres-Rivas, Hector; Fernandez-Fernandez, Luis; Velasco-Albendea, Francisco Javier; Garcia-Clemente, Marta; Lopez-Gonzalez, Francisco
dc.date.accessioned 2026-03-10T11:51:26Z
dc.date.available 2026-03-10T11:51:26Z
dc.date.issued 2025-09
dc.identifier.citation Ariza-Prota M, Pérez-Pallarés J, Barisione E, Cruz-Rueda JJ, Onyancha S, Usturoi D, et al. Enhancing diagnostic precision: a multicentric study of endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy in lymphoproliferative disorders. ERJ Open Res. septiembre de 2025;11(5):00775-2024. doi:10.1183/23120541.00775-2024
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/25254
dc.description.abstract BACKGROUND: The diagnostic accuracy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of lymphoma has a low overall sensitivity. The lack of tissue architecture obtained by cytological needles decreases the diagnostic accuracy for diagnosis and subtyping of de novo and relapsed mediastinal lymphomas. This study compares the sensitivity of EBUS-TBNA and endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy (EBUS-TMC) for both initial lymphoma diagnosis and recurrent cases, analyses safety, and evaluates the number of mediastinoscopies that could potentially be avoided due to this novel technique. METHODS: A multicentre retrospective observational study conducted on 40 patients who underwent both EBUS-TBNA and EBUS-TMC in the same procedure in which a definitive diagnosis of lymphoma was obtained from January 2023 to January 2024. EBUS-TBNA and EBUS-TMC were performed in the same lymph node station. RESULTS: The overall sensitivity of EBUS-TMC was significantly higher compared to EBUS-TBNA alone and EBUS-TBNA+flow cytometry (95% versus 15% versus 25%). In new lymphoma cases, the sensitivity of EBUS-TMC surpassed that of EBUS-TBNA and EBUS-TBNA+flow cytometry (92% versus 15% versus 14%). In recurrent cases, EBUS-TMC showed a sensitivity of 100%, while EBUS-TBNA and EBUS-TBNA+flow cytometry had lower yields of 14% and 41%, respectively. No complications were reported. CONCLUSIONS: EBUS-TMC demonstrates superior sensitivity compared to EBUS-TBNA in diagnosing and subtyping lymphoma, both in suspected new cases and recurrences. This technique reduces the need for procedural repetitions and avoids more invasive and costly interventions such as mediastinoscopy.
dc.language.iso eng
dc.publisher EUROPEAN RESPIRATORY SOC JOURNALS LTD
dc.rights Atribución/Reconocimiento 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es
dc.title Enhancing diagnostic precision: a multicentric study of endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy in lymphoproliferative disorders
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 40927540
dc.relation.publisherversion https://publications.ersnet.org/lookup/doi/10.1183/23120541.00775-2024
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.1183/23120541.00775-2024
dc.journal.title Erj Open Research
dc.identifier.essn 2312-0541


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta