Repositorio Dspace

Endoscopic ultrasound cytologic brushing vs endoscopic ultrasound - fine needle aspiration for cytological diagnosis of cystic pancreatic lesions. A multicenter, randomized open-label trial

Mostrar el registro sencillo del ítem

dc.contributor.author Larino-Noia, José
dc.contributor.author de-la-Iglesia, Daniel
dc.contributor.author Iglesias-García, Julio
dc.contributor.author Macías, Manuel
dc.contributor.author López-Martín, Aurelio
dc.contributor.author Legaz, María-Luisa
dc.contributor.author Vila, Juan
dc.contributor.author Reyes, Antonio
dc.contributor.author Abdulkader, Ihab
dc.contributor.author Enrique-Domínguez-Muñoz, J
dc.date.accessioned 2026-01-22T07:34:26Z
dc.date.available 2026-01-22T07:34:26Z
dc.date.issued 2018
dc.identifier.citation Lariño-Noia J, De La Iglesia D, Iglesias-García J, Macías M, López Martín A, Legaz ML, et al. Endoscopic ultrasound cytologic brushing vs endoscopic ultrasound: fine needle aspiration for cytological diagnosis of cystic pancreatic lesions. A multicenter, randomized open-label trial. Rev Esp Enferm Dig [Internet]. 2018 [citado 19 de enero de 2026]; Disponible en: https://online.reed.es/fichaArticulo.aspx?iarf=685765748238-414277195163
dc.identifier.issn 1130-0108
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/23951
dc.description.abstract INTRODUCTION: the incidence of cystic pancreatic lesions (CPL) in the asymptomatic population is increasing. Achieving a preoperative diagnosis of CPL still remains a challenge. OBJECTIVES: to evaluate the diagnostic accuracy of the cytological diagnosis of CPL from samples obtained by cytology brush versus standard endoscopic ultrasound fine needle aspiration (EUS-FNA). METHODS: a multicenter, randomized, open-label trial was performed of EUS-cytology brush (EUS-EB) versus EUS-FNA for the cytological diagnosis of CPL. Patients that underwent EUS-FNA with a CPL > 15 mm were included and randomized into two groups: group I, EUS-EB; group II, EUS-FNA. The final diagnosis was based on the histological evaluation of surgical specimens and clinical parameters, imaging and a five year follow-up in non-operated patients. The main outcome was the diagnostic accuracy of both methods. Secondary outcomes were the diagnostic adequacy of specimens and the rate of adverse events. Data were compared using the Chi-squared test. An intention to treat (ITT) and per-protocol (PP) analysis were performed. RESULTS: sixty-five patients were included in the study, 31 in group I and 34 in group II. Three patients initially randomized to group I were changed to group II as it was impossible to obtain a sample using the brush. The mean size of the CPL was 28.2 mm (range 16-60 mm). The diagnostic accuracy of EUS-EB was not superior to EUS-FNA, neither in the ITT nor the PP analysis (44.8% vs 41.1%, p = 0.77 and 38.4% vs 45.9%, p = 0.55). CONCLUSIONS: EUS-EB does not improve the diagnostic accuracy of CPL in comparison with EUS-FNA.
dc.language.iso eng
dc.publisher ARAN EDICIONES, S A
dc.rights Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es *
dc.subject.mesh Aged
dc.subject.mesh Cytological Techniques
dc.subject.mesh Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects/methods
dc.subject.mesh Female
dc.subject.mesh Follow-Up Studies
dc.subject.mesh Humans
dc.subject.mesh Male
dc.subject.mesh Middle Aged
dc.subject.mesh Pancreatic Cyst/diagnosis/diagnostic imaging/pathology
dc.subject.mesh Reproducibility of Results
dc.title Endoscopic ultrasound cytologic brushing vs endoscopic ultrasound - fine needle aspiration for cytological diagnosis of cystic pancreatic lesions. A multicenter, randomized open-label trial
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 29685048
dc.relation.publisherversion https://online.reed.es/fichaArticulo.aspx?iarf=685765748238-414277195163
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.17235/reed.2018.5449/2017
dc.journal.title Revista Española de Enfermedades Digestivas
dc.identifier.essn 2340-4167


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta