Repositorio Dspace

Increased Systemic Malondialdehyde Levels and Decreased Mo/Co, Co/Fe2+ Ratios in Patients with Long-Term Dental Titanium Implants and Amalgams

Mostrar el registro sencillo del ítem

dc.contributor.author Cabana-Muñoz, María-Eugenia
dc.contributor.author Parmigiani-Izquierdo, José-María
dc.contributor.author Camacho-Alonso, Fabio
dc.contributor.author Joaquin-Merino, José
dc.date.accessioned 2026-01-19T16:08:27Z
dc.date.available 2026-01-19T16:08:27Z
dc.date.issued 2019-01
dc.identifier.citation Cabaña-Muñoz ME, Parmigiani-Izquierdo JM, Camacho Alonso F, Merino JJ. Increased Systemic Malondialdehyde Levels and Decreased Mo/Co, Co/Fe2+ Ratios in Patients with Long-Term Dental Titanium Implants and Amalgams. JCM. 12 de enero de 2019;8(1):86.
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/23774
dc.description.abstract INTRODUCTION: the biological safety of dental biomaterials has been questioned in human studies. MATERIAL AND METHODS: Several heavy metals/oligoelements were compared by Inductive Coupled Mass Spectrometry (ICP-MS) in hair samples from 130 patients (n = 54 patients with long-term titanium dental implants and amalgams (A + I group), 51 patients with long-term dental amalgam alone (A group), as well as controls (n = 25: without dental materials) of similar age. All patients (except controls) had had titanium dental implants and/or dental amalgams for at least 10 years (average: 17). We evaluated whether A + I patients could present higher systemic malondialdehyde levels (MDA) as compared to the A group. RESULTS: The A + I group have lower molybdenum levels (A + I) and reduced Mo/Co and Mo/Fe(2+) ratios, which could predispose them to oxidative stress by raising MDA levels as compared to the A group alone; our findings suggest that higher Co levels could enhance oxidative stress in the A + I group. However, there were no differences on metals from titanium alloy (Ti-6Al), Cr from crowns or Hg(2+), Sn, Zn(2+), Cu(2+) levels between the A + I and A groups. CONCLUSION: patients with long-term dental titanium and amalgams have systemic oxidative stress due to rising MDA levels and lower Mo/Co and Mo/Fe(2+) ratios than those with amalgams alone.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución/Reconocimiento 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es *
dc.title Increased Systemic Malondialdehyde Levels and Decreased Mo/Co, Co/Fe2+ Ratios in Patients with Long-Term Dental Titanium Implants and Amalgams
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 30642082
dc.relation.publisherversion https://www.mdpi.com/2077-0383/8/1/86
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.3390/jcm8010086
dc.journal.title Journal of Clinical Medicine
dc.identifier.essn 2077-0383


Ficheros en el ítem