Repositorio Dspace

Clinical Management With High-Frequency Ultrasound of Recurrent Submental Abscess Formation After Filler Placement: Bacterial Contamination or Immune-Mediated Adverse Event?

Mostrar el registro sencillo del ítem

dc.contributor.author Nicola, Andrada-Gabriela
dc.contributor.author Pricop, Marius-Octavian
dc.contributor.author Ramos-Medina, Benito
dc.date.accessioned 2025-11-26T11:46:47Z
dc.date.available 2025-11-26T11:46:47Z
dc.date.issued 2024-04-23
dc.identifier.citation Nicola AG, Pricop MO, Ramos-Medina B. Clinical Management With High-Frequency Ultrasound of Recurrent Submental Abscess Formation After Filler Placement: Bacterial Contamination or Immune-Mediated Adverse Event? Cureus [Internet]. 23 de abril de 2024 [citado 25 de noviembre de 2025]; Disponible en: https://www.cureus.com/articles/246078-clinical-management-with-high-frequency-ultrasound-of-recurrent-submental-abscess-formation-after-filler-placement-bacterial-contamination-or-immune-mediated-adverse-event
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/22685
dc.description.abstract The authors present a case of a 29-year-old female patient with a recurrent submental abscess formation after chin augmentation with highly reticulated hyaluronic acid filler. We evaluate the possible cause of this complication and the result after clinical management with ultrasound-guided injection of hyaluronidase. We highlight the prevention, assessment and treatment with real-time imaging of hyaluronidase injection in the affected area, as a predictable approach for both the patient and the physician.
dc.language.iso spa
dc.publisher SPRINGERNATURE
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0 *
dc.title Clinical Management With High-Frequency Ultrasound of Recurrent Submental Abscess Formation After Filler Placement: Bacterial Contamination or Immune-Mediated Adverse Event?
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 38659708
dc.relation.publisherversion https://www.cureus.com/articles/246078-clinical-management-with-high-frequency-ultrasound-of-recurrent-submental-abscess-formation-after-filler-placement-bacterial-contamination-or-immune-mediated-adverse-event
dc.identifier.doi 10.7759/cureus.58878
dc.journal.title Cureus Journal of Medical Science
dc.identifier.essn 2168-8184