Repositorio Dspace

How does head position affect laryngeal vision with a video laryngeal mask airway?

Mostrar el registro sencillo del ítem

dc.contributor.author Castillo-Monzón, Caridad-G
dc.contributor.author Marroquín-Valz, Hugo-Antonio
dc.contributor.author Gaszynski, Tomász
dc.contributor.author Cayuela, Manuel
dc.contributor.author Orozco, Javier
dc.contributor.author Ratajczyk, Pawel
dc.date.accessioned 2025-11-21T08:48:23Z
dc.date.available 2025-11-21T08:48:23Z
dc.date.issued 2024-12-16
dc.identifier.citation Castillo-Monzón CG, Marroquín-Valz HA, Gaszynski T, Cayuela M, Orozco J, Ratajczyk P. How does head position affect laryngeal vision with a video laryngeal mask airway? Front Med. 16 de diciembre de 2024;11:1469225.
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/22021
dc.description.abstract BACKGROUND: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway. METHODS: This prospective, observational, transversal, and analytical study was performed in 72 consecutive patients. In the same patient, laryngeal vision was first assessed with the head and neck in the sniffing position and then with the head in the neutral position. Procedures were performed by the same investigator. The assessment of the laryngeal view was performed using two classifications: Cormack-Lehane classification and Brimacombe classification. The placement of the device was considered adequate when the Cormack-Lehane rating was between 1 and 2 and the Brimacombe rating between 2 and 4. RESULTS: In this study, 72 patients participated. In the assessment of the glottis using the Cormack-Lehane classification for fibre-optic view, laryngeal visibility was adequate in 64 (88.89%) patients in the neutral position and in 65 (90, 28%) patients in the sniffing position (p?>?0.05). In the fibre-optic view of the glottis, evaluated using the Brimacombe classification, laryngeal visibility was adequate in 68 (93%) patients in the neutral position and in 69 (95%) patients in the sniffing position (p?>?0.05). There was no statistically significant difference in the rate of success between the sniffing position (70 patients, 97.22% success rate) and the neutral position (67 patients, 93.06% success rate) during the first insertion attempt. Two patients required a second attempt in the sniffing position, while five patients required a second attempt in the neutral position. CONCLUSION: An adequate sniffing position did not result in a better glottic view than the neutral position. Additional manoeuvres were equal in both positions. The head-neck position does not influence on the placement of a third-generation SAD.
dc.language.iso eng
dc.publisher FRONTIERS MEDIA SA
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/es/  *
dc.title How does head position affect laryngeal vision with a video laryngeal mask airway?
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 39741507
dc.relation.publisherversion https://www.frontiersin.org/articles/10.3389/fmed.2024.1469225/full
dc.identifier.doi 10.3389/fmed.2024.1469225
dc.journal.title Frontiers in Medicine
dc.identifier.essn 2296-858X


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional