Repositorio Dspace

Manifold analysis of the P-wave changes induced by pulmonary vein isolation during cryoballoon procedure

Mostrar el registro sencillo del ítem

dc.contributor.author Martínez-Mateu, Laura
dc.contributor.author Melgarejo-Meseguer, Francisco-M
dc.contributor.author Muñoz-Romero, Sergio
dc.contributor.author Gimeno-Blanes, Francisco-Javier
dc.contributor.author García-Alberola, Arcadio
dc.contributor.author Rocher-Ventura, Sara
dc.contributor.author Saiz, Javier
dc.contributor.author Rojo-Álvarez, José-Luis
dc.date.accessioned 2025-11-19T12:39:33Z
dc.date.available 2025-11-19T12:39:33Z
dc.date.issued 2023-03
dc.identifier.issn 0010-4825
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/21154
dc.description.abstract BACKGROUND/AIM: In atrial fibrillation (AF) ablation procedures, it is desirable to know whether a proper disconnection of the pulmonary veins (PVs) was achieved. We hypothesize that information about their isolation could be provided by analyzing changes in P-wave after ablation. Thus, we present a method to detect PV disconnection using P-wave signal analysis. METHODS: Conventional P-wave feature extraction was compared to an automatic feature extraction procedure based on creating low-dimensional latent spaces for cardiac signals with the Uniform Manifold Approximation and Projection (UMAP) method. A database of patients (19 controls and 16 AF individuals who underwent a PV ablation procedure) was collected. Standard 12-lead ECG was recorded, and P-waves were segmented and averaged to extract conventional features (duration, amplitude, and area) and their manifold representations provided by UMAP on a 3-dimensional latent space. A virtual patient was used to validate these results further and study the spatial distribution of the extracted characteristics over the whole torso surface. RESULTS: Both methods showed differences between P-wave before and after ablation. Conventional methods were more prone to noise, P-wave delineation errors, and inter-patient variability. P-wave differences were observed in the standard leads recordings. However, higher differences appeared in the torso region over the precordial leads. Recordings near the left scapula also yielded noticeable differences. CONCLUSIONS: P-wave analysis based on UMAP parameters detects PV disconnection after ablation in AF patients and is more robust than heuristic parameterization. Moreover, additional leads different from the standard 12-lead ECG should be used to detect PV isolation and possible future reconnections better.
dc.language.iso eng
dc.publisher PERGAMON-ELSEVIER SCIENCE LTD
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/ *
dc.subject.mesh Humans
dc.subject.mesh Pulmonary Veins
dc.subject.mesh Atrial Fibrillation
dc.subject.mesh Heart Conduction System
dc.subject.mesh Electrocardiography
dc.subject.mesh Cryosurgery/methods
dc.subject.mesh Catheter Ablation/methods
dc.subject.mesh Treatment Outcome
dc.subject.mesh Recurrence
dc.title Manifold analysis of the P-wave changes induced by pulmonary vein isolation during cryoballoon procedure
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 36812811
dc.relation.publisherversion https://linkinghub.elsevier.com/retrieve/pii/S0010482523001208
dc.identifier.doi 10.1016/j.compbiomed.2023.106655
dc.journal.title Computers in Biology and Medicine
dc.identifier.essn 1879-0534