Mostrar el registro sencillo del ítem
| dc.contributor.author | Angulo, Javier-C | |
| dc.contributor.author | Giammo, Alessandro | |
| dc.contributor.author | Queissert, Fabian | |
| dc.contributor.author | Schoenburg, Sandra | |
| dc.contributor.author | González-Enguita, Carmen | |
| dc.contributor.author | Gonsior, Andreas | |
| dc.contributor.author | Romero, Antonio | |
| dc.contributor.author | Martins, Francisco-E | |
| dc.contributor.author | Antunes-Lopes, Tiago | |
| dc.contributor.author | González, Raquel | |
| dc.contributor.author | Szczesniewski, Juliusz | |
| dc.contributor.author | Téllez, Carlos | |
| dc.contributor.author | Cruz, Francisco | |
| dc.contributor.author | Rourke, Keith | |
| dc.date.accessioned | 2025-11-18T09:33:28Z | |
| dc.date.available | 2025-11-18T09:33:28Z | |
| dc.date.issued | 2024-04 | |
| dc.identifier.citation | Angulo JC, Giammò A, Queissert F, Schönburg S, González-Enguita C, Gonsior A, et al. The effectiveness of adjustable trans-obturator male system (ATOMS) in radiated patients is reduced: A propensity score-matched analysis. BJUI Compass. abril de 2024;5(4):506-14. | |
| dc.identifier.issn | 2688-4526 | |
| dc.identifier.uri | https://sms.carm.es/ricsmur/handle/123456789/20859 | |
| dc.description.abstract | OBJECTIVES: This study aimed to compare the effectiveness and safety of the adjustable trans-obturator male system (ATOMS®) to treat post-prostatectomy incontinence (PPI) in radiated patients compared with non-radiated patients, using propensity score-matching analysis to enhance the validity of the comparison. PATIENTS AND METHODS: Consecutive men with PPI treated with silicone-covered scrotal port ATOMS (A.M.I., Feldkirch, Austria) in nine different institutions between 2016 and 2022 were included. Preoperative assessment evaluated 24-h pad usage, urethroscopy and urodynamics, if indicated. Propensity score-matching analysis was based on age, length of follow-up, previous PPI treatment, previous bladder neck stricture, androgen deprivation and pad usage. The primary endpoint was dry rate, defined as no pads post-operatively with a security pad allowed. The secondary endpoints were complications, device removal and self-perceived satisfaction with the Patient Global Impression of Improvement (PGI-I) scale. RESULTS: Of the 710 included patients, 342 were matched, and the study groups were balanced for the baseline matched variables. The mean baseline 24-h pad was 4.8 in both groups (p-=-0.48). The mean follow-up was 27.5-±-18.6-months, which was also equivalent between groups (p-=-0.36). The primary outcome was achieved in 73 (42.7%) radiated patients and in 115 (67.3%) non-radiated patients (p-<-0.0001). The mean pad count at the last follow-up was 1.5 and 0.8, respectively (p-<-0.0001). There was no significant difference in complications (p-=-0.94), but surgical revision and device explant rates were higher (p-=-0.03 and p-=-0.01, respectively), and the proportion of patients highly satisfied (PGI-I-=-1) was lower in the radiated group (p-=-0.01). At sensitivity analysis, the study was found to be reasonably robust to hidden bias. CONCLUSION: ATOMS implantation significantly outperformed in patients without adjuvant radiation over radiated patients. | |
| dc.language.iso | eng | |
| dc.publisher | Wiley | |
| dc.subject.mesh | Adult | |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Cross-Sectional Studies | |
| dc.subject.mesh | Obesity/epidemiology | |
| dc.subject.mesh | Sleep/physiology | |
| dc.subject.mesh | Metabolic Syndrome/epidemiology | |
| dc.subject.mesh | Life Style | |
| dc.subject.mesh | Risk Factors | |
| dc.title | The effectiveness of adjustable trans-obturator male system (ATOMS) in radiated patients is reduced: A propensity score-matched analysis | |