Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?

Mostrar el registro sencillo del ítem

dc.contributor.author García-Medina, José-Javier
dc.contributor.author Ferreras, Antonio
dc.contributor.author del-Río-Vellosillo, Mónica
dc.contributor.author Zanon-Moreno, Vicente
dc.contributor.author Santos-Bueso, Enrique
dc.contributor.author Gallego-Pinazo, Roberto
dc.contributor.author Dolores-Pinazo-Duran, María
dc.date.accessioned 2026-10-21T06:12:35Z
dc.date.available 2026-10-21T06:12:35Z
dc.date.issued 2015
dc.identifier.citation Garcia-Medina JJ, Del Rio-Vellosillo M, Zanon-Moreno V, Santos-Bueso E, Gallego-Pinazo R, Ferreras A, et al. Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc? BioMed Research International. 2015;2015:1-8. doi:10.1155/2015/813242
dc.identifier.issn 2314-6133
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/28776
dc.description.abstract The visual outcome obtained after cataract removal may progressively decline because of posterior capsular opacification (PCO). This condition can be treated by creating an opening in the posterior lens capsule by Nd:YAG laser capsulotomy. PCO optical imperfections cause several light reflection, refraction, and diffraction phenomena, which may interfere with the functional and structural tests performed in different ocular locations for the diagnosis and follow-up of ocular disease, like macular and optic nerve diseases. Some parameters measured by visual field examinations, scanning laser polarimetry, and optical coherence tomography (OCT) have changed after PCO removal. Imaging quality also changes following capsulotomy. Consequently, the results of ancillary tests in pseudophakic eyes for studying ocular diseases like glaucoma or maculopathies should be correlated with other clinical examinations, for example, slit-lamp biomicroscopy or funduscopy. If PCO is clinically significant, a new baseline should be set for future comparisons following capsulotomy when using automated perimetry and scanning laser polarimetry. To perform OCT in the presence of PCO, reliable examinations (considering signal strength) apparently guarantee that measurements are not influenced by PCO.
dc.language.iso eng
dc.rights Atribución/Reconocimiento 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es *
dc.subject.mesh Capsule Opacification/pathology/surgery
dc.subject.mesh Diagnostic Techniques, Ophthalmological
dc.subject.mesh Humans
dc.subject.mesh Optic Disk/pathology
dc.subject.mesh Posterior Capsulotomy
dc.subject.mesh Retina/pathology
dc.title Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?
dc.type info:eu-repo/semantics/article 
dc.identifier.pmid 26167499
dc.relation.publisherversion http://www.hindawi.com/journals/bmri/2015/813242/
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.1155/2015/813242
dc.journal.title Biomed Research International
dc.identifier.essn 2314-6141


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta