Repositorio Dspace

Do technological tools improve reliability in ankle dorsiflexion assessment? A study across healthy and injured individuals

Mostrar el registro sencillo del ítem

dc.contributor.author Cánovas-Ambit, Germán
dc.contributor.author Godínez-Leal, Jorge
dc.contributor.author Baño-Alcaraz, Aitor
dc.contributor.author López-Nicolás, Manuel
dc.contributor.author García-Vidal, José-Antonio
dc.date.accessioned 2026-03-10T11:51:57Z
dc.date.available 2026-03-10T11:51:57Z
dc.date.issued 2026-02
dc.identifier.citation Cánovas-Ambit G, Leal JG, Baño-Alcaraz A, Nicolas ML, García-Vidal JA. Do technological tools improve reliability in ankle dorsiflexion assessment? A study across healthy and injured individuals. Journal of Electromyography and Kinesiology. febrero de 2026;86:103087. doi:10.1016/j.jelekin.2025.103087
dc.identifier.issn 1050-6411
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/25287
dc.description.abstract BACKGROUND: The objective was to examine the intra- and inter-rater reliability of three instruments for measuring ankle dorsiflexion (ADF) range of motion (ROM) and degree of asymmetry in the Weight-Bearing Lunge Test (WBLT). Additionally, the study evaluated the agreement between these tools in both asymptomatic and symptomatic populations. METHODS: Sixty-five participants were included, comprising 32 healthy individuals and 33 subjects presenting ankle pathology. Measurements were conducted on two separate occasions by two independent assessors using distinct methods to quantify ADF-ROM and asymmetry during the WBLT. RESULTS: Veloflex demonstrated strong intra- and inter-rater reliability, with intraclass correlation coefficients (ICCs) consistently above 0.88, for both ADF-ROM measurement and asymmetry detection across symptomatic and asymptomatic groups. Furthermore, an acceptable agreement was observed between Veloflex and the tape measure in the symptomatic cohort, while agreement between Veloflex and the Dorsiflex app was suboptimal. CONCLUSION: The findings indicate that Veloflex is a reliable tool for assessing ADF-ROM and asymmetry in both healthy and pathological cases. While the tape measure offers a viable alternative to Veloflex in symptomatic assessments, substitution of Veloflex with the Dorsiflex app is not supported due to inconsistent agreement.
dc.language.iso eng
dc.publisher ELSEVIER SCI LTD
dc.rights Atribución/Reconocimiento-NoComercial 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by-nc/4.0/deed.es
dc.subject.mesh Humans
dc.subject.mesh Reproducibility of Results
dc.subject.mesh Male
dc.subject.mesh Female
dc.subject.mesh Adult
dc.subject.mesh Ankle Joint/physiopathology/physiology
dc.subject.mesh Range of Motion, Articular/physiology
dc.subject.mesh Ankle Injuries/physiopathology/diagnosis
dc.subject.mesh Young Adult
dc.subject.mesh Middle Aged
dc.subject.mesh Weight-Bearing
dc.subject.mesh Observer Variation
dc.title Do technological tools improve reliability in ankle dorsiflexion assessment? A study across healthy and injured individuals
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 41265287
dc.relation.publisherversion https://linkinghub.elsevier.com/retrieve/pii/S1050641125001130
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.1016/j.jelekin.2025.103087
dc.journal.title Journal of Electromyography and Kinesiology
dc.identifier.essn 1873-5711


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta