In vitro biocompatibility testing of 3D printing and conventional resins for occlusal devices

Mostrar el registro sencillo del ítem

dc.contributor.author Guerrero-Gironés, Julia
dc.contributor.author López-García, Sergio
dc.contributor.author Pecci-Lloret, María-Pilar
dc.contributor.author Pecci-Lloret, María-Pilar
dc.contributor.author Rodríguez-Lozano, Francisco-Javier
dc.contributor.author García-Bernal, David
dc.date.accessioned 2025-12-03T11:13:53Z
dc.date.available 2025-12-03T11:13:53Z
dc.date.issued 2022-08
dc.identifier.citation Guerrero-Gironés J, López-García S, Pecci-Lloret MR, Pecci-Lloret MP, Rodríguez Lozano FJ, García-Bernal D. In vitro biocompatibility testing of 3D printing and conventional resins for occlusal devices. Journal of Dentistry. agosto de 2022;123:104163.
dc.identifier.issn 0300-5712
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/22994
dc.description.abstract OBJECTIVE: To assess and compare the in vitro biocompatibility of new resins (Keysplint Soft (Keystone Industries), NextDent Ortho Rigid (3D System), and Freeprint Splint (Detax)) and traditional resins (Orthocryl (Dentaurum)) used for dental splints. METHODS: Standardized discs (n = 40) and 1:1, 1:2, and 1:4 extracts of the tested materials were prepared. Human gingival fibroblasts (hGFs) were isolated from gingival tissues. Different biological tests were carried out, including MTT assays to assess cell metabolic activity, cell migration assays, cell cytoskeleton staining, cell apoptosis, generation of intracellular reactive oxygen species (ROS), and scanning electron microscopy (SEM). Statistical analyses were performed using one-way ANOVA and Tukey's post hoc test (p<0.05). RESULTS: MTT experiments showed that Freeprint Splint significantly reduces the hGF metabolic activity (p<0.001), whereas SEM analysis showed almost no cells adhered on its surface. Cell migration was significantly lower after exposure to undiluted extracts of Freeprint Splint at 48 and 72 h (p<0.001). Cell cytoskeleton staining assays showed fewer attached cells in 1:1 and 1:2 dilutions of Freeprint Splint. Annexin-V and 7-AAD staining assays showed that only cells exposed to Keysplint Soft extracts displayed similar cell viability to the control group. Finally, ROS levels detected in undiluted extracts of all resins were significantly enhanced compared to the control group (p<0.001). CONCLUSIONS: The 3D-printed resins and the conventional dental resin showed a similar biocompatibility, except for Freeprint Splint, which was the most cytotoxic on hGFs. CLINICAL SIGNIFICANCE: 3D printing has been on the rise in recent years and its use in daily clinical practice is expanding over time. Two of the three 3D-printed resins tested in this study performed as well in the cytotoxicity tests as the conventional one, supporting their use, but caution and further testing are required.
dc.language.iso eng
dc.publisher ELSEVIER SCI LTD
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional 
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0
dc.subject.mesh Humans
dc.subject.mesh In Vitro Techniques
dc.subject.mesh Materials Testing
dc.subject.mesh Printing, Three-Dimensional
dc.subject.mesh Reactive Oxygen Species
dc.subject.mesh Splints
dc.title In vitro biocompatibility testing of 3D printing and conventional resins for occlusal devices
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 35577252
dc.relation.publisherversion https://linkinghub.elsevier.com/retrieve/pii/S0300571222002196
dc.identifier.doi 10.1016/j.jdent.2022.104163
dc.journal.title Journal of Dentistry
dc.identifier.essn 1879-176X