Repositorio Dspace

Validity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software

Mostrar el registro sencillo del ítem

dc.contributor.author Hurtado-Avilés, José
dc.contributor.author Santonja-Medina, Fernando
dc.contributor.author León-Muñoz, Vicente-J
dc.contributor.author Sainz-de-Baranda, Pilar
dc.contributor.author Collazo-Dieguez, Mónica
dc.contributor.author Cabañero-Castillo, Mercedes
dc.contributor.author Ponce-Garrido, Ana-Belén
dc.contributor.author Fuentes-Santos, Victoria-Eugenia
dc.contributor.author Santonja-Renedo, Fernando
dc.contributor.author González-Ballester, Miriam
dc.contributor.author Sánchez-Martínez, Francisco-Javier
dc.contributor.author Fiorita, Pietro-Gino
dc.contributor.author Sanz-Mengibar, José-Manuel
dc.contributor.author Alcaraz-Belzunces, Joaquín
dc.contributor.author Ferrer-López, Vicente
dc.contributor.author Andújar-Ortuño, Pilar
dc.date.accessioned 2025-11-24T15:14:07Z
dc.date.available 2025-11-24T15:14:07Z
dc.date.issued 2022-04
dc.identifier.citation Hurtado-Avilés J, Santonja-Medina F, León-Muñoz VJ, Sainz De Baranda P, Collazo-Diéguez M, Cabañero-Castillo M, et al. Validity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software. IJERPH. 12 de abril de 2022;19(8):4655.
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/22381
dc.description.abstract The Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software's validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart. The observers re-measured the same radiographic studies on three separate occasions three months later but on conventional X-ray films. The differences between the mean bias errors (MBE) within the experience groups were statistically significant between the experts (software) and novices (manual) (p < 0.001) and between the novices (software) and novices (manual) (p = 0.005). When measured with the software, the intra-group error in the expert group was MBE = 1.71 ± 0.61° and the intraclass correlation coefficient (ICC (2,1)) = 0.986, and in the novice group, MBE = 1.9 ± 0.67° and ICC (2,1) = 0.97. There was almost a perfect concordance among the two measurement methods, ICC (2,1) = 0.998 and minimum detectable change (MCD95) < 0.4°. Control of the intrinsic error sources enabled obtaining inter- and intra-observer MDC95 < 0.5° in the two experience groups and with the two measurement methods. The computer-aided software TraumaMeter increases the validity and reliability of Cobb angle measurements concerning manual measurement.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional 
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/es/  *
dc.subject.mesh Adolescent
dc.subject.mesh Humans
dc.subject.mesh Radiography
dc.subject.mesh Reproducibility of Results
dc.subject.mesh Research Design
dc.subject.mesh Scoliosis/diagnostic imaging
dc.subject.mesh Software
dc.subject.mesh Spine
dc.title Validity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 35457522
dc.relation.publisherversion https://www.mdpi.com/1660-4601/19/8/4655
dc.identifier.doi 10.3390/ijerph19084655
dc.journal.title International Journal of Environmental Research and Public Health
dc.identifier.essn 1660-4601


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional  Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional 

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta