Repositorio Dspace

Evaluation of the Diagnostic Capability of Spectralis SD-OCT 8 x 8 Posterior Pole Software with the Grid Tilted at 7 Degrees and Horizontalized in Glaucoma

Mostrar el registro sencillo del ítem

dc.contributor.author Alvarez-Sarrion, Aurora
dc.contributor.author García-Medina, José-Javier
dc.contributor.author Palazon-Cabanes, Ana
dc.contributor.author Pinazo-Duran, María-Dolores
dc.contributor.author Del-Rio-Vellosillo, Monica
dc.date.accessioned 2025-11-18T12:50:25Z
dc.date.available 2025-11-18T12:50:25Z
dc.date.issued 2024-02
dc.identifier.citation Alvarez-Sarrion A, Garcia-Medina JJ, Palazon-Cabanes A, Pinazo-Duran MD, Del-Rio-Vellosillo M. Evaluation of the Diagnostic Capability of Spectralis SD-OCT 8 × 8 Posterior Pole Software with the Grid Tilted at 7 Degrees and Horizontalized in Glaucoma. JCM. 9 de febrero de 2024;13(4):1016.
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/20983
dc.description.abstract Background: The goal was to evaluate the diagnostic capability of different parameters obtained with the posterior pole (PP) software in Spectralis SD-OCT with the 8 × 8 grid tilted at 7° and horizontalized in glaucomatous eyes. Methods: A total of 299 eyes were included, comprising 136 healthy eyes and 163 with primary open-angle glaucoma (POAG). The following segmentations were evaluated: complete retina, retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), GCL and inner plexiform layer (GCLIPL), ganglion cell complex (GCC), outer plexiform layer and outer nuclear layer (OPLONL), inner retinal layer (IRL), and outer retinal layer (ORL). Different patterns of macular damage were represented using heatmaps for each studied layer, where the areas under the curve (AUROC) values and a retinal thickness cutoff point were defined to discriminate POAG patients. Results: There was not any difference in the diagnostic capability for detecting glaucoma between the grid tilted at 7° and horizontalized. The macular segmentations that offer the highest diagnostic ability in glaucoma discrimination were, in the following order, RNFL (AUROC = 0.796), GCC (AUROC = 0.785), GCL (AUROC = 0.784), GCLIPL (AUROC = 0.770), IRL (AUROC = 0.755), and the complete retina (AUROC = 0.752). In contrast, ORL and OPLONL do not appear to be helpful for discriminating POAG. Conclusions: Some results of PP software may be useful for discriminating POAG.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/ *
dc.title Evaluation of the Diagnostic Capability of Spectralis SD-OCT 8 x 8 Posterior Pole Software with the Grid Tilted at 7 Degrees and Horizontalized in Glaucoma
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 38398328
dc.relation.publisherversion https://www.mdpi.com/2077-0383/13/4/1016
dc.identifier.doi 10.3390/jcm13041016
dc.journal.title Journal of Clinical Medicine
dc.identifier.essn 2077-0383


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 España Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 España

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta