A sex-dependent algorithm including kappa free light chain for multiple sclerosis diagnosis

Mostrar el registro sencillo del ítem

dc.contributor.author Maroto-Garcia,Julia
dc.contributor.author Manez,Minerva
dc.contributor.author Martinez-Escribano,Ana
dc.contributor.author Hachmaoui-Ridaoui,Ahlam
dc.contributor.author Ortiz,Carmen
dc.contributor.author Abalos-Garcia,Carmen
dc.contributor.author Gonzalez,Inmaculada
dc.contributor.author de-la-Torre,Angela-Garcia
dc.contributor.author Ruiz-Galdon,Maximiliano
dc.date.accessioned 2025-10-20T14:40:23Z
dc.date.available 2025-10-20T14:40:23Z
dc.date.issued 2024-12
dc.identifier.citation Maroto¿García J, Mañez M, Martínez¿Escribano A, Hachmaoui¿Ridaoui A, Ortiz C, Ábalos¿García C, et al. A sex¿dependent algorithm including kappa free light chain for multiple sclerosis diagnosis. Scand J Immunol. diciembre de 2024;100(6):e13421.
dc.identifier.issn 0300-9475
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/20487
dc.description.abstract Multiple sclerosis (MS) diagnosis includes the presence of restricted oligoclonal bands (OCB) in cerebrospinal fluid (CSF), but it has several limitations, as it is an observer-dependent time-consuming technique and offers a dichotomous result. Thus kappa free light chains (KFLC) have emerged as a quantitative alternative. However, the cut-off values for KFLC have not been well established yet and it is not clear if differences between sexes exist. We aim to evaluate these and to compare the diagnostic accuracy of KFLC concentrations and their related indexes versus OCB. For that purpose, paired CSF and serum samples were collected and immediately processed for albumin, total protein, immunoglobulins and OCB, then frozen at -20 degrees C. KFLC was measured in a BN II (Siemens Healthineers, Germany). KFLC-derived indexes were calculated. Diagnostic accuracy was evaluated by the area under the curve (AUC), Youden's index and odds ratio. From the 193 patients included, 56 were classified as MS according to the 2017 McDonald criteria. K-index, Q KFLC and Reiber's diagram showed good accuracy in MS diagnosis when studied distinguishing between sexes, similar to OCB. Cut-offs for K-index and Q KFLC change substantially between sex having the highest AUC similar than OCB. A sex-dependent algorithm combining the use of K-index, Q KFLC and OCB yields the highest diagnostic accuracy. In conclusion, CSF KFLC measurement is a rapid, quantitative and easy-to-standardize tool that used through the proposed sex-dependent algorithm may reduce the number of manual OCB tests performed.
dc.language.iso eng
dc.publisher WILEY
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/ *
dc.subject.mesh Humans
dc.subject.mesh Female
dc.subject.mesh Male
dc.subject.mesh Multiple Sclerosis/diagnosis/cerebrospinal fluid/blood/immunology
dc.subject.mesh Algorithms
dc.subject.mesh Adult
dc.subject.mesh Immunoglobulin kappa-Chains/cerebrospinal fluid/blood
dc.subject.mesh Middle Aged
dc.subject.mesh Oligoclonal Bands/cerebrospinal fluid/blood
dc.subject.mesh Sex Factors
dc.subject.mesh Young Adult
dc.subject.mesh Biomarkers/blood/cerebrospinal fluid
dc.title A sex-dependent algorithm including kappa free light chain for multiple sclerosis diagnosis
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 39506182
dc.relation.publisherversion https://dx.doi.org/10.1111/sji.13421
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.1111/sji.13421
dc.journal.title Scandinavian Journal of Immunology
dc.identifier.essn 1365-3083