Applicator-Based Versus Bulk-Bottle Delivery of the Same Alcoholic Chlorhexidine: A Single-Center, Non-Randomized Pilot Micro-Costing Study of Two Surgical Skin-Antisepsis Workflows

Mostrar el registro sencillo del ítem

dc.contributor.author Guillen-Grima, Francisco
dc.contributor.author García-García, María-Pilar
dc.contributor.author Guillen-Aguinaga, Laura
dc.contributor.author Romanco-Moreno, Belen
dc.contributor.author Eizaguirre-Artolozaga, Ander
dc.contributor.author Aguinaga-Ontoso, Enrique
dc.date.accessioned 2026-11-11T09:05:14Z
dc.date.available 2026-11-11T09:05:14Z
dc.date.issued 2026-10-15
dc.identifier.citation Guillen-Grima F, Garcia-Garcia MP, Guillen-Aguinaga L, Romanco-Moreno B, Eizaguirre-Artolozaga A, Aguinaga-Ontoso E. Applicator-Based Versus Bulk-Bottle Delivery of the Same Alcoholic Chlorhexidine: A Single-Center, Non-Randomized Pilot Micro-Costing Study of Two Surgical Skin-Antisepsis Workflows. Healthcare. 15 de octubre de 2026;14(20):3456. doi:10.3390/healthcare14203456
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/29147
dc.description.abstract Background/Objectives: Delivery format may change the resources consumed by surgical skin antisepsis even when the antiseptic is unchanged. We compared two workflows using identical 2% chlorhexidine in 70% isopropyl alcohol: a single-use pre-filled applicator and our center's bulk-bottle protocol. Methods: Single-center, non-randomized pilot micro-costing study (hospital perspective, ?2024) of 20 elective abdominal procedures (10 per workflow) performed by non-overlapping surgeon groups. Time was measured stepwise to completion of application, excluding the air-drying interval; waste was weighed. Results: Two bulk-protocol steps, decanting onto a cloth and blotting excess with gauze (39.8 s combined), have no applicator counterpart. Residual alcoholic chlorhexidine was 72.8% lower and total waste 27.9% lower (?42.3 g; 95% CI ?62.1 to ?22.6). Materials differed by ?1.17 per procedure (?3.26 on the same regulatory basis), a difference that reverses if reprocessing is valued below about 78% of its average allocated cost. Aggregate workflow time differed by ?29.8 s (95% CI ?61.4 to ?1.9) and total cost, 85% of it time valued and realizable only if released minutes become usable activity, by ??7.57 (?14.38 to ?1.56). Case mix biased both in favor of the applicator: among unilateral hernia repairs (seven vs. four) they fell to ?7.3 s (?33.0 to +19.6) and ??2.74 (?8.26 to +3.05), whereas waste differences were unchanged. Operator nesting makes intervals for time, cost and liquid waste likely too narrow. Conclusions: With the same antiseptic, the applicator workflow removes two handling steps and was associated with less wasted antiseptic. Whether it saves time or money requires a study crossing operators over workflows and timing drying.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución/Reconocimiento 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es *
dc.title Applicator-Based Versus Bulk-Bottle Delivery of the Same Alcoholic Chlorhexidine: A Single-Center, Non-Randomized Pilot Micro-Costing Study of Two Surgical Skin-Antisepsis Workflows
dc.type info:eu-repo/semantics/article
dc.relation.publisherversion https://www.mdpi.com/2227-9032/14/20/3456
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.3390/healthcare14203456
dc.journal.title Healthcare
dc.identifier.essn 2227-9032