Repositorio Dspace

Automatic Supporting System for Regionalization of Ventricular Tachycardia Exit Site in Implantable Defibrillators

Mostrar el registro sencillo del ítem

dc.contributor.author Sanroman-Junquera, Margarita
dc.contributor.author Mora-Jiménez, Inmaculada
dc.contributor.author Almendral, Jesus
dc.contributor.author García-Alberola, Arcadio
dc.contributor.author Luis-Rojo-Alvarez, José
dc.date.accessioned 2026-10-21T06:10:22Z
dc.date.available 2026-10-21T06:10:22Z
dc.date.issued 2015-04-24
dc.identifier.citation Sanromán-Junquera M, Mora-Jiménez I, Almendral J, García-Alberola A, Rojo-Álvarez JL. Automatic Supporting System for Regionalization of Ventricular Tachycardia Exit Site in Implantable Defibrillators. Talkachova A, editor. PLoS ONE. 24 de abril de 2015;10(4):e0124514. doi:10.1371/journal.pone.0124514
dc.identifier.issn 1932-6203
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/28723
dc.description.abstract Electrograms stored in Implantable Cardioverter Defibrillators (ICD-EGM) have been proven to convey useful information for roughly determining the anatomical location of the Left Ventricular Tachycardia exit site (LVTES). Our aim here was to evaluate the possibilities from a machine learning system intended to provide an estimation of the LVTES anatomical region with the use of ICD-EGM in the situation where 12-lead electrocardiogram of ventricular tachycardia are not available. Several machine learning techniques were specifically designed and benchmarked, both from classification (such as Neural Networks (NN), and Support Vector Machines (SVM)) and regression (Kernel Ridge Regression) problem statements. Classifiers were evaluated by using accuracy rates for LVTES identification in a controlled number of anatomical regions, and the regression approach quality was studied in terms of the spatial resolution. We analyzed the ICD-EGM of 23 patients (18±10 EGM per patient) during left ventricular pacing and simultaneous recording of the spatial coordinates of the pacing electrode with a navigation system. Several feature sets extracted from ICD-EGM (consisting of times and voltages) were shown to convey more discriminative information than the raw waveform. Among classifiers, the SVM performed slightly better than NN. In accordance with previous clinical works, the average spatial resolution for the LVTES was about 3 cm, as in our system, which allows it to support the faster determination of the LVTES in ablation procedures. The proposed approach also provides with a framework suitable for driving the design of improved performance future systems.
dc.language.iso eng
dc.rights Atribución/Reconocimiento 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es *
dc.subject.mesh Aged
dc.subject.mesh Defibrillators, Implantable
dc.subject.mesh Electrocardiography
dc.subject.mesh Female
dc.subject.mesh Humans
dc.subject.mesh Male
dc.subject.mesh Middle Aged
dc.subject.mesh Reproducibility of Results
dc.subject.mesh Support Vector Machine
dc.subject.mesh Tachycardia, Ventricular/diagnosis/physiopathology
dc.title Automatic Supporting System for Regionalization of Ventricular Tachycardia Exit Site in Implantable Defibrillators
dc.type info:eu-repo/semantics/article 
dc.identifier.pmid 25910170
dc.relation.publisherversion https://dx.plos.org/10.1371/journal.pone.0124514
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.1371/journal.pone.0124514
dc.journal.title Plos One


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento 4.0 Internacional