Cervical Stiffness Measured by the Cervisense Intravaginal Probe for Identification of Imminent Delivery in Symptomatic Threatened Preterm Labor

Mostrar el registro sencillo del ítem

dc.contributor.author Samper-Girona, Andrea
dc.contributor.author Aiartzaguena, Amaia
dc.contributor.author Burgos, Jorge
dc.contributor.author Muñoz-González, María-D
dc.contributor.author Gil, María-M
dc.contributor.author Valladolid, Amelia
dc.contributor.author Urones, Alain
dc.contributor.author Cobo, Teresa
dc.contributor.author Ferrero, Silvia
dc.contributor.author Goya, María
dc.contributor.author del-Barco-Martínez, Ester
dc.contributor.author Blanco-Carnero, José-Eliseo
dc.contributor.author Prats-Rodríguez, Pilar
dc.contributor.author Molina, Francisca-S
dc.date.accessioned 2026-09-17T12:13:46Z
dc.date.available 2026-09-17T12:13:46Z
dc.date.issued 2026-04-27
dc.identifier.issn 1010-660X
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/28120
dc.description.abstract Background and Objectives: Risk stratification in symptomatic threatened preterm labor (TPTL) remains challenging, particularly for clinically actionable time horizons. We evaluated whether quantitative cervical stiffness measured with the Cervisense Intravaginal Probe discriminates between women who will and will not deliver within 7, 10, or 14 days after presentation and assessed its discriminative performance alone and in combination with transvaginal cervical length. Materials and Methods: We conducted a multicenter, non-interventional study across 10 obstetric emergency units in Spain. Eligible participants were women aged ? 18 years with a live singleton pregnancy at 28(+0) to 36(+6) weeks, regular uterine contractions, intact membranes, and cervical dilatation < 2 cm on speculum examination. Cervical stiffness was measured at presentation using torsional wave elastography with the Cervisense Intravaginal Probe. Cervical length was measured by transvaginal ultrasonography following international standards. Outcomes were delivery within 7, 10, and 14 days after presentation. Discrimination was quantified using the area under the receiver operating characteristic curve (AUC). An explanatory multivariable logistic regression model for delivery within 14 days included cervical stiffness, cervical length, and covariates selected as potential confounders. Results: Among 305 participants, 17 (5.6%) delivered within 7 days, 19 (6.2%) within 10 days, and 24 (7.9%) within 14 days. Mean cervical stiffness was lower among women who delivered within 14 days than among those who did not (8.63 vs. 14.82 kPa; p = 0.048). Cervical length was shorter among women who delivered within 7, 10, and 14 days (all p < 0.001). Discrimination for cervical stiffness was moderate (AUC, 0.66, 0.64, and 0.73 for ?7, ?10, and ?14 days) and higher for cervical length (AUC, 0.80, 0.77, and 0.78). The combined model achieved the highest discrimination (AUC, 0.85, 0.85, and 0.86). In the ?14-day explanatory model, higher log-transformed cervical stiffness was associated with lower odds of delivery (OR, 0.907; 95% CI, 0.828 to 0.995; p = 0.039), as was longer cervical length (OR per 1 mm, 0.910; 95% CI, 0.876 to 0.946; p < 0.001). Conclusions: In symptomatic TPTL, Cervisense-derived cervical stiffness showed moderate discrimination for short-term delivery and provided complementary information to cervical length, with improved discrimination when both measures were combined. These findings support future studies developing multivariable prediction models that incorporate quantitative cervical consistency.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución/Reconocimiento 4.0 Internaciona
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es *
dc.subject.mesh Humans
dc.subject.mesh Female
dc.subject.mesh Pregnancy
dc.subject.mesh Obstetric Labor, Premature/diagnosis/physiopathology
dc.subject.mesh Adult
dc.subject.mesh Cervix Uteri/physiopathology/diagnostic imaging
dc.subject.mesh Spain
dc.subject.mesh Cervical Length Measurement/methods
dc.subject.mesh Elasticity Imaging Techniques/methods/instrumentation
dc.subject.mesh ROC Curve
dc.subject.mesh Logistic Models
dc.title Cervical Stiffness Measured by the Cervisense Intravaginal Probe for Identification of Imminent Delivery in Symptomatic Threatened Preterm Labor
dc.type info:eu-repo/semantics/article 
dc.identifier.pmid 42195083
dc.relation.publisherversion https://www.mdpi.com/1648-9144/62/5/830
dc.type.version info:eu-repo/semantics/publishedVersion 
dc.identifier.doi 10.3390/medicina62050830
dc.journal.title MEDICINA-LITHUANIA
dc.identifier.essn 1648-9144