Repositorio Dspace

Long-term outcomes of hydrodynamic ultra-thin strut sirolimus-eluting stent with fluoropolymer containing triflusal: VELAZQUEZ-EPIC26 study.

Mostrar el registro sencillo del ítem

dc.contributor.author Linares-Vicente, José-Antonio
dc.contributor.author Sainz-Laso, Fermín
dc.contributor.author Casanova-Sandoval, Juan-Manuel
dc.contributor.author Rumoroso-Cueva, José-Ramón
dc.contributor.author Gómez-Menchero, Antonio
dc.contributor.author Gómez-Hospital, Joan-Antoni
dc.contributor.author Pérez-Guerrero, Ainhoa
dc.contributor.author Santos-Martínez, Sandra
dc.contributor.author Fernández-Portales, Javier
dc.contributor.author Romaní, Sebastián
dc.contributor.author García-del-Blanco, Bruno
dc.contributor.author Ocaranza-Sánchez, Raymundo
dc.contributor.author Urbano-Carrillo, Cristóbal
dc.contributor.author García-San-Roman, Koldobika
dc.contributor.author Vinhas, Hugo
dc.contributor.author Cid-Álvarez, Belén
dc.contributor.author Sanchis-Fores, Juan
dc.contributor.author Telleria-Arrieta, Miren
dc.contributor.author Torres-Bosco, Alfonso
dc.contributor.author Pinar-Bermúdez, Eduardo
dc.contributor.author Méndez-Castro, José-Juan
dc.contributor.author Lozano-Ruiz-de-Poveda, Fernando
dc.contributor.author Pérez-de-Prado, Armando
dc.contributor.author de-la-Torre-Hernández, José-María
dc.date.accessioned 2026-04-06T11:05:17Z
dc.date.available 2026-04-06T11:05:17Z
dc.date.issued 2026-03
dc.identifier.citation Linares Vicente JA, Sainz Laso F, Casanova Sandoval JM, Rumoroso Cueva JR, Gómez Menchero A, Gómez Hospital JA, et al. Long-term outcomes of hydrodynamic ultra-thin strut sirolimus-eluting stent with fluoropolymer containing triflusal: VELAZQUEZ-EPIC26 study. Cardiovascular Revascularization Medicine. marzo de 2026;84:26-33. doi:10.1016/j.carrev.2025.07.009
dc.identifier.issn 1553-8389 
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/25686
dc.description.abstract BACKGROUND: A new-generation coronary sirolimus eluting-stent(SES), whose novel characteristics are summarized in ultra-thin oval-shaped hydrodynamic struts (68 ?m) and abluminal drug release with permanent fluoropolymer containing the platelet aggregation inhibitor triflusal, showed low target lesion failure(TLF) and absence of stent thrombosis(ST) at 1 year in a first-in-human study. Long-term clinical efficacy is unknown. We aim to investigate long-term clinical efficacy of this new SES in a real-world population undergoing PCI for native coronary artery. METHODS: VELAZQUEZ-EPIC26 is a prospective, observational and multicentre study of a large cohort undergoing PCI with the new SES (ihtDEStiny?). Primary endpoint was TLF at 2 years (composite of cardiovascular death, target vessel myocardial infarction, or clinically driven target lesion revascularization). Secondary clinical safety and efficacy endpoints included definitive or probable ST, target vessel failure (TVF), major adverse cardiac events (MACE), and BARC 3-5 bleeding. RESULTS: Between 2021 and 2023, 406 patients (mean age 65 ± 11 years, 75 % males, 26 % diabetes) were included. 519 SES were implanted over 482 target lesions. Mean stent diameter and length were 3.03 ± 0.49 mm and 22 ± 7,6 mm respectively. Procedural success rate was 97.3 %. TLF at 2 years was 2,2 % (n = 9). There were 3 cardiovascular deaths (0,7 %), none related to SES complications. 1 very late definite stent thrombosis was reported (0,2 %, n = 1). TVF, MACE and BARC 3-5 bleeding rates at years were 3 % (n = 12), 3,2 % (n = 13) and 3,5 % (n = 14) respectively. CONCLUSIONS: In a large real-world population undergoing PCI for native coronary artery, a new hydrodynamic ultra-thin strut SES with abluminal permanent fluoropolymer containing triflusal shows low TLF and very low ST rates at 2 years.
dc.language.iso eng
dc.publisher ELSEVIER
dc.rights Atribución/Reconocimiento 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by/4.0/deed.es *
dc.subject.mesh Humans
dc.subject.mesh Male
dc.subject.mesh Aged
dc.subject.mesh Female
dc.subject.mesh Prospective Studies
dc.subject.mesh Treatment Outcome
dc.subject.mesh Drug-Eluting Stents
dc.subject.mesh Coronary Artery Disease/diagnostic imaging/mortality/therapy
dc.subject.mesh Percutaneous Coronary Intervention/adverse effects/instrumentation/mortality
dc.subject.mesh Middle Aged
dc.subject.mesh Time Factors
dc.subject.mesh Prosthesis Design
dc.subject.mesh Sirolimus/administration & dosage/adverse effects
dc.subject.mesh Cardiovascular Agents/administration & dosage/adverse effects
dc.subject.mesh Risk Factors
dc.subject.mesh Platelet Aggregation Inhibitors/administration & dosage/adverse effects
dc.subject.mesh Salicylates/administration & dosage/adverse effects
dc.subject.mesh Polymers
dc.title Long-term outcomes of hydrodynamic ultra-thin strut sirolimus-eluting stent with fluoropolymer containing triflusal: VELAZQUEZ-EPIC26 study.
dc.type info:eu-repo/semantics/article 
dc.identifier.pmid 40713212
dc.relation.publisherversion https://linkinghub.elsevier.com/retrieve/pii/S1553838925003926
dc.type.version info:eu-repo/semantics/publishedVersion 
dc.identifier.doi 10.1016/j.carrev.2025.07.009
dc.journal.title Cardiovascular Revascularization Medicine : Including Molecular Interventions
dc.identifier.essn 1878-0938


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta