Repositorio Dspace

New Stent Retriever Technology Versus Standard Devices for Anterior Large Vessel Thrombectomy: A Multicenter Study

Mostrar el registro sencillo del ítem

dc.contributor.author Puig, Josep
dc.contributor.author Dolz, Guillem
dc.contributor.author Werner, Mariano
dc.contributor.author Daunis-i-Estadella, Pepus
dc.contributor.author Comas-Cufi, Marc
dc.contributor.author Tomasello, Alejandro
dc.contributor.author González, Eva
dc.contributor.author Manso-del-Cano, Xabier
dc.contributor.author Vega, Pedro
dc.contributor.author Murias, Eduardo
dc.contributor.author Bravo, Isabel
dc.contributor.author Jiménez, Elvira
dc.contributor.author Aparici-Robles, Fernando
dc.contributor.author Sanchis, Juan-Manuel
dc.contributor.author Remollo, Sebastia
dc.contributor.author Castaño, Carlos
dc.contributor.author Moreu, Manuel
dc.contributor.author López-Frias, Alfonso
dc.contributor.author Terceno, Mikel
dc.contributor.author Silva, Yolanda
dc.contributor.author Chirife, Oscar
dc.contributor.author López-Rueda, Antonio
dc.contributor.author Martínez-Fernández, Javier
dc.contributor.author Méndez, José-Carlos
dc.contributor.author Sagredo, Antonio
dc.contributor.author Diaz-Pérez, Jose
dc.contributor.author Cuba, Victor
dc.contributor.author Llibre, José-Carlos
dc.contributor.author Aguilar, Yeray
dc.contributor.author SanRoman, Luis
dc.contributor.author Blasco, Jordi
dc.date.accessioned 2026-03-06T14:20:39Z
dc.date.available 2026-03-06T14:20:39Z
dc.date.issued 2025-11
dc.identifier.citation Puig J, Dolz G, Werner M, Daunis-i-Estadella P, Comas-Cufí M, Tomasello A, et al. New Stent Retriever Technology Versus Standard Devices for Anterior Large Vessel Thrombectomy: A Multicenter Study. Journal of Neuroimaging. noviembre de 2025;35(6):e70111. doi:10.1111/jon.70111
dc.identifier.issn 1051-2284
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/24818
dc.description.abstract BACKGROUND AND PURPOSE: Guidelines recommend stent retrievers (SRs) for treating large vessel occlusion (LVO) stroke. We assessed noninferiority of the iNtercept (iVascular) SR with a self-expanding basket on a pusher wire versus contemporary SRs (CSRs) using propensity score (PS) matching analysis. METHODS: We analyzed data from the ROSSETTI multicenter registry of patients with anterior circulation LVO to compare procedural (recanalization rates according to the modified Thrombolysis In Cerebral Infarction (mTICI) score and procedural complications), clinical (modified Rankin Scale at 90 days), and safety (symptomatic intracranial hemorrhage, mortality at 90 days) outcomes of patients treated with iNtercept or CSRs (Solitaire, Trevo, and EmboTrap) as a first-line strategy, with or without balloon-guide catheter (BGC + SR, BCG - SR) after PS matching. Non-inferiority of iNtercept was established if the prespecified lower bound of the 95% confidence interval was over -10%. RESULTS: A total of 164 and 132 patients treated first-line by iNtercept were matched to 656 and 132 patients treated first-line by CSR + BGC and CSR - BGC, respectively. After matching, successful reperfusion (mTICI2b/3) after first-line strategy was achieved in 53.7% and 54.8% in the iNtercept versus CSR + BGC groups, respectively (absolute difference, -0.1%), and 53.8% and 51.3% in the iNtercept versus CSR - BGC, respectively (2.6%). Final reperfusion rates and favorable 90-day outcomes were similar. iNtercept had fewer sICH, procedural complications, and emboli in a new territory than CSR + BGC, and fewer procedural complications than CSR - BGC. CONCLUSIONS: This multicenter registry with PS matching demonstrated the non-inferiority of iNtercept to approved CSRs for successful reperfusion in LVO acute ischemic stroke.
dc.language.iso eng
dc.publisher WILEY
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.subject.mesh Humans
dc.subject.mesh Female
dc.subject.mesh Male
dc.subject.mesh Aged
dc.subject.mesh Thrombectomy/instrumentation/methods
dc.subject.mesh Stents
dc.subject.mesh Registries
dc.subject.mesh Treatment Outcome
dc.subject.mesh Middle Aged
dc.subject.mesh Aged, 80 and over
dc.title New Stent Retriever Technology Versus Standard Devices for Anterior Large Vessel Thrombectomy: A Multicenter Study
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 41311321
dc.relation.publisherversion https://onlinelibrary.wiley.com/doi/10.1111/jon.70111
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.1111/jon.70111
dc.journal.title Journal of Neuroimaging
dc.identifier.essn 1552-6569


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta