Repositorio Dspace

Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects

Mostrar el registro sencillo del ítem

dc.contributor.author Martín-San-Agustin, Rodrigo
dc.contributor.author García-Vidal, José-A
dc.contributor.author Canovas-Ambit, German
dc.contributor.author Arenas-Della-Vecchia, Aurelio
dc.contributor.author López-Nicolás, Manuel
dc.contributor.author Medina-Mirapeix, Francesc
dc.date.accessioned 2026-01-22T07:39:00Z
dc.date.available 2026-01-22T07:39:00Z
dc.date.issued 2019-11
dc.identifier.citation Martín-San Agustín R, García-Vidal JA, Cánovas-Ambit G, Arenas-Della Vecchia A, López-Nicolás M, Medina-Mirapeix F. Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects. JCM. 2 de noviembre de 2019;8(11):1851.
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/24012
dc.description.abstract The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland-Altmann plots. Intra- and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Both instruments showed excellent correlation for all movements (r range from 0.992 to 0.999). The intra- and inter-rater reliability were excellent (ICC range from 0.95 to 0.99 and 0.90 to 0.98, respectively). Intra-rater reliability showed SEMs <1.38% and <5.19% and inter-rater reliability SEMs <2.26% and <5.22% for asymptomatic and symptomatic, respectively. Veloflex-IDA is a valid and reliable alternative to measure the upper limb joints' ROM and it can be used in clinical practice and research after basic training.
dc.language.iso eng
dc.publisher MDPI
dc.rights Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es *
dc.title Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 31684077
dc.relation.publisherversion https://www.mdpi.com/2077-0383/8/11/1851
dc.type.version info:eu-repo/semantics/publishedVersion
dc.identifier.doi 10.3390/jcm8111851
dc.journal.title Journal of Clinical Medicine
dc.identifier.essn 2077-0383


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta