Mostrar el registro sencillo del ítem
| dc.contributor.author | Martín-San-Agustin, Rodrigo | |
| dc.contributor.author | García-Vidal, José-A | |
| dc.contributor.author | Canovas-Ambit, German | |
| dc.contributor.author | Arenas-Della-Vecchia, Aurelio | |
| dc.contributor.author | López-Nicolás, Manuel | |
| dc.contributor.author | Medina-Mirapeix, Francesc | |
| dc.date.accessioned | 2026-01-22T07:39:00Z | |
| dc.date.available | 2026-01-22T07:39:00Z | |
| dc.date.issued | 2019-11 | |
| dc.identifier.citation | Martín-San Agustín R, García-Vidal JA, Cánovas-Ambit G, Arenas-Della Vecchia A, López-Nicolás M, Medina-Mirapeix F. Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects. JCM. 2 de noviembre de 2019;8(11):1851. | |
| dc.identifier.uri | https://sms.carm.es/ricsmur/handle/123456789/24012 | |
| dc.description.abstract | The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland-Altmann plots. Intra- and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Both instruments showed excellent correlation for all movements (r range from 0.992 to 0.999). The intra- and inter-rater reliability were excellent (ICC range from 0.95 to 0.99 and 0.90 to 0.98, respectively). Intra-rater reliability showed SEMs <1.38% and <5.19% and inter-rater reliability SEMs <2.26% and <5.22% for asymptomatic and symptomatic, respectively. Veloflex-IDA is a valid and reliable alternative to measure the upper limb joints' ROM and it can be used in clinical practice and research after basic training. | |
| dc.language.iso | eng | |
| dc.publisher | MDPI | |
| dc.rights | Atribución/Reconocimiento-NoComercial-CompartirIgual 4.0 Internacional | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/deed.es | * |
| dc.title | Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects | |
| dc.type | info:eu-repo/semantics/article | |
| dc.identifier.pmid | 31684077 | |
| dc.relation.publisherversion | https://www.mdpi.com/2077-0383/8/11/1851 | |
| dc.type.version | info:eu-repo/semantics/publishedVersion | |
| dc.identifier.doi | 10.3390/jcm8111851 | |
| dc.journal.title | Journal of Clinical Medicine | |
| dc.identifier.essn | 2077-0383 |