Repositorio Dspace

Visual Performance at All Distances and Patient Satisfaction With a New Aspheric Inverted Meniscus Intraocular Lens

Mostrar el registro sencillo del ítem

dc.contributor.author Marin, José-M
dc.contributor.author Hervella, Lucía
dc.contributor.author Villegas, Eloy
dc.contributor.author Robles, Consuelo
dc.contributor.author Alcon, Encarna
dc.contributor.author Yago, Ines
dc.contributor.author Artal, Pablo
dc.date.accessioned 2025-11-26T11:36:48Z
dc.date.available 2025-11-26T11:36:48Z
dc.date.issued 2023-09
dc.identifier.citation Marín JM, Hervella L, Villegas E, Robles C, Alcón E, Yago I, et al. Visual Performance at All Distances and Patient Satisfaction With a New Aspheric Inverted Meniscus Intraocular Lens. J Refract Surg. septiembre de 2023;39(9):582-8.
dc.identifier.issn 1081-597X
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/22605
dc.description.abstract PURPOSE: To evaluate visual performance, spectacle independence, and quality of vision of new intraocular lenses (IOLs) for presbyopia correction with an aspheric inverted meniscus optical design (ArtIOLs; Voptica SL) in patients undergoing bilateral cataract surgery. METHODS: In this prospective study, 60 eyes from 30 patients implanted bilaterally with Art40 and Art70 IOLs were included. These new IOLs were designed with an inverted meniscus shape to improve the peripheral performance and with aspheric surfaces to induce different amounts of negative spherical aberration in each IOL model. Distance-corrected and uncorrected through-focus visual acuities and contrast sensitivity were measured 1 to 3 months after surgery. Twenty-eight patients answered Patient Reported Spectacle Independence (PRSIQ) and Quality of Vision (QoV) questionnaires. RESULTS: Mean monocular (Art40 and Art70) and binocular (Art40/70) corrected distance visual acuities (CDVA) were zero logMAR (20/20). Binocular uncorrected distance visual acuity (UDVA) at far, intermediate (66 cm), and near (40 cm) distances was 0.00 ± 0.01, 0.01 ± 0.03, and 0.09 ± 0.09 logMAR, respectively. Spectacle independence was achieved by 24 (85.7%) patients for far and intermediate vision and 20 patients (71.4%) for near vision. The number of patients never reporting experiencing glare, halos, and starbursts was 28, 27, and 26 (100%, 96.4%, and 92.9%), respectively. CONCLUSIONS: The binocular combination of two ArtIOLs models (Art40 and Art70) significantly extended the depth of focus up to at least 40 cm. This combination resulted in a full range of vision with a high level of spectacle independence and without the compromise of halos or dysphotopsias. [J Refract Surg. 2023;39(9):582-588.].
dc.language.iso eng
dc.publisher SLACK INC
dc.rights Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0 *
dc.subject.mesh Humans
dc.subject.mesh Patient Satisfaction
dc.subject.mesh Prospective Studies
dc.subject.mesh Lenses, Intraocular
dc.subject.mesh Cataract Extraction
dc.subject.mesh Meniscus
dc.title Visual Performance at All Distances and Patient Satisfaction With a New Aspheric Inverted Meniscus Intraocular Lens
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 37675912
dc.relation.publisherversion https://journals.healio.com/doi/10.3928/1081597X-20230802-01
dc.identifier.doi 10.3928/1081597X-20230802-01
dc.journal.title Journal of Refractive Surgery
dc.identifier.essn 1938-2391


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta