Mostrar el registro sencillo del ítem
| dc.contributor.author | Álvarez-Ortega, Carlos-Antonio | |
| dc.contributor.author | Ruiz, Miguel-Ángel | |
| dc.contributor.author | Solorzano-Guillén, César | |
| dc.contributor.author | Barrera, Alberto | |
| dc.contributor.author | Toquero-Ramos, Jorge | |
| dc.contributor.author | Martínez-Alday, Jesús-Daniel | |
| dc.contributor.author | Grande, Carlos | |
| dc.contributor.author | Segura, José-María | |
| dc.contributor.author | García-Alberola, Arcadio | |
| dc.contributor.author | Morina-Vázquez, Pablo | |
| dc.contributor.author | Ferrero-de-Loma-Osorio, Ángel | |
| dc.contributor.author | Villuendas, Roger | |
| dc.contributor.author | Cozar, Rocío | |
| dc.contributor.author | Fe-Arcocha, María | |
| dc.contributor.author | Ibáñez, Alicia | |
| dc.contributor.author | Peinado, Rafael | |
| dc.date.accessioned | 2025-11-26T11:34:37Z | |
| dc.date.available | 2025-11-26T11:34:37Z | |
| dc.date.issued | 2023-07 | |
| dc.identifier.citation | Álvarez-Ortega CA, Ruiz MA, Solórzano-Guillén C, Barrera A, Toquero-Ramos J, Martínez-Alday JD, et al. Time to -30°C as a predictor of acute success during cryoablation in patients with atrial fibrillation. Cardiol J. 31 de agosto de 2023;30(4):534-42. | |
| dc.identifier.issn | 1897-5593 | |
| dc.identifier.uri | https://sms.carm.es/ricsmur/handle/123456789/22533 | |
| dc.description.abstract | BACKGROUND: Freezing rate of second-generation cryoballoon (CB) is a biophysical parameter that could assist pulmonary vein isolation. The aim of this study is to assess freezing rate (time to reach -30°C ([TT-30C]) as an early predictor of acute pulmonary vein isolation using the CB. METHODS: Biophysical data from CB freeze applications within a multicenter, nation-wide CB ablation registry were gathered. Successful application (SA), was defined as achieving durable intraprocedural vein isolation. And SA with time to isolation under 60 s (SA-TTI<60) as achieving durable vein isolation in under 60 s. Logistic regressions were performed and predictive models were built for the data set. RESULTS: 12,488 CB applications from 1,733 atrial fibrillation (AF) ablation procedures were included within 27 centers from a Spanish CB AF ablation registry. SA was achieved in 6,349 of 9,178 (69.2%) total freeze applications, and SA-TTI<60 was obtained in 2,673 of 4,784 (55.9%) freezes where electrogram monitoring was present. TT-30C was shorter in the SA group (33.4 ± 9.2 vs 39.3 ± 12.1 s; p < 0.001) and SA-TTI<60 group (31.8 ± 7.6 vs. 38.5 ± 11.5 s; p < 0.001). Also, a 10 s increase in TT-30C was associated with a 41% reduction in the odds for an SA (odds ratio [OR] 0.59; 95% confidence interval [CI] 0.56-0.63) and a 57% reduction in the odds for achieving SA-TTI<60 (OR 0.43; 95% CI 0.39-0.49), when corrected for electrogram visualization, vein position, and application order. CONCLUSIONS: Time to reach -30°C is an early predictor of the quality of a CB application and can be used to guide the ablation procedure even in the absence of electrogram monitoring. | |
| dc.language.iso | eng | |
| dc.publisher | VIA MEDICA | |
| dc.rights | Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0 | * |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Atrial Fibrillation/diagnosis/surgery | |
| dc.subject.mesh | Cryosurgery/adverse effects/methods | |
| dc.subject.mesh | Treatment Outcome | |
| dc.subject.mesh | Time Factors | |
| dc.subject.mesh | Pulmonary Veins/surgery | |
| dc.subject.mesh | Catheter Ablation/methods | |
| dc.subject.mesh | Recurrence | |
| dc.title | Time to-30°C as a predictor of acute success during cryoablation in patients with atrial fibrillation | |