Repositorio Dspace

Validity and reliability of a computer-assisted system method to measure axial vertebral rotation

Mostrar el registro sencillo del ítem

dc.contributor.author Hurtado-Avilés, José
dc.contributor.author León-Muñoz, Vicente-J
dc.contributor.author Sanz-Mengibar, José-Manuel
dc.contributor.author Santonja-Renedo, Fernando
dc.contributor.author Andújar-Ortuño, Pilar
dc.contributor.author Collazo-Dieguez, Mónica
dc.contributor.author Ferrer-López, Vicente
dc.contributor.author Roca-González, Joaquín
dc.contributor.author Sergeevich-Kurochka, Konstantsin
dc.contributor.author Cabañero-Castillo, Mercedes
dc.contributor.author Alcaraz-Belzunces, Joaquín
dc.contributor.author Ruiz-Cambra, Nieves-Aide
dc.contributor.author Fuentes-Santos, Victoria-Eugenia
dc.contributor.author Ponce-Garrido, Ana-Belén
dc.contributor.author González-Ballester, Miriam
dc.contributor.author Sánchez-Martínez, Francisco-Javier
dc.contributor.author Campuzano-Melgarejo, Andrés
dc.contributor.author Gino-Fiorita, Pietro
dc.contributor.author Santonja-Medina, Fernando
dc.date.accessioned 2025-11-20T12:50:30Z
dc.date.available 2025-11-20T12:50:30Z
dc.date.issued 2022-03
dc.identifier.citation Hurtado-Avilés J, León-Muñoz VJ, Sanz-Mengibar JM, Santonja-Renedo F, Andújar-Ortuño P, Collazo-Diéguez M, et al. Validity and reliability of a computer-assisted system method to measure axial vertebral rotation. Quant Imaging Med Surg. marzo de 2022;12(3):1706-15.
dc.identifier.issn 2223-4292
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/21816
dc.description.abstract BACKGROUND: Axial vertebral rotation and Cobb's angle are essential parameters for analysing adolescent idiopathic scoliosis. This study's scope evaluates the validity and absolute reliability of application software based on a new mathematical equation to determine the axial vertebral rotation in digital X-rays according to Raimondi's method in evaluators with different degrees of experience. METHODS: Twelve independent evaluators with different experience levels measured 33 scoliotic curves in 21 X-rays with the software on three separate occasions, separated one month. Using the same methodology, the observers re-measured the same radiographic studies three months later but on X-ray films and in a conventional way. RESULTS: Both methods show good validity and reliability, and the intraclass correlation coefficients are almost perfect. According to our results, the software increases 1.7 times the validity and 1.9 times the absolute reliability of axial vertebral rotation on digital X-rays according to Raimondi's method, compared to the conventional manual measurement. CONCLUSIONS: The intra-group and inter-group agreement of the measurements with the software shows equal or minor variations than with the manual method, among the different measurement sessions and in the three experience groups. There is almost perfect agreement between the two measurement methods, so the equation and the software may be helpful to increase the accuracy in the axial vertebral rotation assessment.
dc.language.iso eng
dc.publisher AME PUBL CO
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/ *
dc.title Validity and reliability of a computer-assisted system method to measure axial vertebral rotation
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 35284293
dc.relation.publisherversion https://qims.amegroups.com/article/view/85007/html
dc.identifier.doi 10.21037/qims-21-575
dc.journal.title Quantitative Imaging in Medicine and Surgery
dc.identifier.essn 2223-4306


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 España Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 España

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta