Repositorio Dspace

Safety and Efficacy of BioMime Sirolimus-Eluting Stent System in All-Comers Real-World Population With Coronary Artery Stenosis: MILES Global Registry

Mostrar el registro sencillo del ítem

dc.contributor.author Hudec, Martín
dc.contributor.author Jeong, Myung-Ho
dc.contributor.author Trillo, Ramiro
dc.contributor.author Ijsselmuiden, Alexander-JJ
dc.contributor.author Gwon, Hyeon-Cheol
dc.contributor.author Chae, In-Ho
dc.contributor.author Wang, Yi-Chih
dc.contributor.author Costa, José-Maques-de
dc.contributor.author Charng, Min-Ji
dc.contributor.author Maskon, Oteh
dc.contributor.author Burgos, José-Moreu
dc.contributor.author Mayurathan, Gnanamoorthy
dc.contributor.author Mateev, Hristo
dc.contributor.author Serra, Antonio
dc.contributor.author Merkely, Bela
dc.contributor.author Cale, Rita
dc.contributor.author Hwang, Shinn-Jang
dc.contributor.author Mar, Guang-Yuan
dc.contributor.author Lawand, Samih
dc.contributor.author Khokhlov, Andriy
dc.contributor.author Montilla, Beatriz-Vaqueizo
dc.contributor.author Valdes, Maríano
dc.contributor.author Sadeghian, Mohammad
dc.date.accessioned 2025-11-20T12:48:27Z
dc.date.available 2025-11-20T12:48:27Z
dc.date.issued 2024-12
dc.identifier.citation Hudec M, Jeong MH, Trillo R, Ijsselmuiden AJJ, Gwon HC, Chae IH, et al. Safety and Efficacy of BioMime Sirolimus-Eluting Stent System in All-Comers Real-World Population With Coronary Artery Stenosis: MILES Global Registry. Cardiol Res. diciembre de 2024;15(6):439-52.
dc.identifier.issn 1923-2829
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/21737
dc.description.abstract BACKGROUND: This study evaluated the safety and efficacy of BioMime sirolimus-eluting stent (SES) system, with an ultra-low strut thickness (65 µm), in real-world all-comers population with coronary artery stenosis (CAD). METHODS: This was a post-marketing, multicenter, single-arm, observational clinical registry among patients undergoing intervention for CAD. Patients were clinically followed up at 1, 9, 12, and 24 months after the index percutaneous coronary intervention. Four major indications, namely long stents of > 30 mm, stents with diameters of 4 and 4.5 mm, bifurcation subgroup, and chronic total occlusion (CTO) were evaluated as pre-specified subsets. RESULTS: A total of 771 patients (1,079 treated lesions) from 23 sites were included in this study. The mean length and diameter of the implanted stents were 25.57 ± 9.35 mm and 3.00 ± 0.44 mm, respectively. The mean minimum lumen diameter before and after the procedure was 1.00 ± 1.69 mm and 2.96 ± 1.35 mm, respectively. The cumulative rates of major adverse cardiovascular events (MACEs) and stent thrombosis (ST) at 1, 9, 12, and 24 months were 1.05%, 3.13%, 4.04%, 5.64% and 0%, 0.13%, 0.28%, 0.28%, respectively. In a subset with > 30 mm long stents, the cumulative rate of MACEs was 0.4%, 4.6%, 5.12%, and 7.01% at 1, 9, 12, and 24 months, respectively. The corresponding rates of ST were 0%, 0.42%, 0.43%, and 0.44%, indicating constant rate of ST after 9 months. In a subset of 4 and 4.5 mm diameter stents, the cumulative rate of MACEs was high (0%, 6.25%, 6.25%, and 10.41%) at 1, 9, 12, and 24 months, respectively. However, there was no case of ST until 24 months. In patients with bifurcation lesions, the cumulative rates of MACEs and ST were 2.46%, 6.32%, 11.53%, 16.21% and 0%, 1.27%, 1.28%, 1.35% at 1, 9, 12, and 24 months follow-up. In patients with chronic total occlusion, the cumulative rates of MACEs and ST were 0.79%, 5.04%, 6.83%, 7.07% and 0%, 0.84%, 0.85%, 0.88% at 1, 9, 12, and 24 months, respectively, indicating constant rate of ST after 9 months. CONCLUSIONS: The BioMime SES demonstrated good safety and efficacy outcomes at 24-month follow-up, with low rates of MACEs and ST in patients with CAD in the real-world setting.
dc.language.iso eng
dc.publisher ELMER PRESS INC
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/ *
dc.title Safety and Efficacy of BioMime Sirolimus-Eluting Stent System in All-Comers Real-World Population With Coronary Artery Stenosis: MILES Global Registry
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 39698009
dc.relation.publisherversion https://cr.elmerpub.com/index.php/cr/article/view/2024
dc.identifier.doi 10.14740/cr1724
dc.journal.title Cardiology Research
dc.identifier.essn 1923-2837


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 España Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 España