Mostrar el registro sencillo del ítem
| dc.contributor.author | López-García, Sergio | |
| dc.contributor.author | Pecci-Lloret, Miguel-Ramón | |
| dc.contributor.author | Pecci-Lloret, María-Pilar | |
| dc.contributor.author | García-Bernal, David | |
| dc.contributor.author | Onate-Sánchez, Ricardo-Elias | |
| dc.date.accessioned | 2025-11-20T07:25:49Z | |
| dc.date.available | 2025-11-20T07:25:49Z | |
| dc.date.issued | 2024-11-06 | |
| dc.identifier.citation | López-García S, Pecci-Lloret MR, Pecci-Lloret MP, García-Bernal D, Oñate-Sánchez RE. Influence of the post-processing protocol on a biocompatible 3D-printed resin. Journal of Prosthodontics. 6 de noviembre de 2024;jopr.13980. | |
| dc.identifier.issn | 1059-941X | |
| dc.identifier.uri | https://sms.carm.es/ricsmur/handle/123456789/21607 | |
| dc.description.abstract | PURPOSE: This study aimed to evaluate the cytotoxicity of a biocompatible 3D-printed resin material for occlusal devices after post-processing with two different high-intensity UV-polymerization devices and two rinsing solvents, in the presence of human gingival fibroblasts (HGFs). MATERIAL AND METHODS: Sample discs from the 3D-printed resin material were printed (2 mm in height and 6 mm in diameter [N = 40]) and divided into 4 groups (n = 10) based on post-processing methods: a high-intensity UV polymerization device with isopropyl alcohol, a high-intensity UV polymerization device with a modified glycol solvent, a UV cleaning and curing unit with isopropyl alcohol, a UV cleaning and curing unit with a modified glycol solvent, and a control group cultured in DMEM medium. Different tests were performed to evaluate their cytocompatibility on HGFs: MTT assay, cell migration assay, cell cytoskeleton staining, scanning electron microscopy (SEM), and cell apoptosis and generation of intracellular reactive oxygen species (ROS). Statistical analyses were performed using one-way ANOVA and the Tukey post hoc test (? = 0.05). RESULTS: Cytocompatibility, MTT assay, cell migration assay, cell cytoskeleton staining, and SEM images were similar, regardless of the post-processing protocol, compared with the control group. CONCLUSIONS: No differences were found in the cytotoxicity of the 3D-printed resin material for occlusal devices after the following post-processing methods: two different UV-polymerization devices and two rinsing solvents (isopropyl alcohol and a modified glycol solvent). | |
| dc.language.iso | eng | |
| dc.publisher | WILEY | |
| dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | |
| dc.rights.uri | Atribución-NoComercial-SinDerivadas 3.0 España | * |
| dc.title | Influence of the post-processing protocol on a biocompatible 3D-printed resin | |
| dc.type | info:eu-repo/semantics/article | |
| dc.identifier.pmid | 39506359 | |
| dc.relation.publisherversion | https://onlinelibrary.wiley.com/doi/10.1111/jopr.13980 | |
| dc.identifier.doi | 10.1111/jopr.13980 | |
| dc.journal.title | Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry | |
| dc.identifier.essn | 1532-849X |