Repositorio Dspace

Influence of the post-processing protocol on a biocompatible 3D-printed resin

Mostrar el registro sencillo del ítem

dc.contributor.author López-García, Sergio
dc.contributor.author Pecci-Lloret, Miguel-Ramón
dc.contributor.author Pecci-Lloret, María-Pilar
dc.contributor.author García-Bernal, David
dc.contributor.author Onate-Sánchez, Ricardo-Elias
dc.date.accessioned 2025-11-20T07:25:49Z
dc.date.available 2025-11-20T07:25:49Z
dc.date.issued 2024-11-06
dc.identifier.citation López-García S, Pecci-Lloret MR, Pecci-Lloret MP, García-Bernal D, Oñate-Sánchez RE. Influence of the post-processing protocol on a biocompatible 3D-printed resin. Journal of Prosthodontics. 6 de noviembre de 2024;jopr.13980.
dc.identifier.issn 1059-941X
dc.identifier.uri https://sms.carm.es/ricsmur/handle/123456789/21607
dc.description.abstract PURPOSE: This study aimed to evaluate the cytotoxicity of a biocompatible 3D-printed resin material for occlusal devices after post-processing with two different high-intensity UV-polymerization devices and two rinsing solvents, in the presence of human gingival fibroblasts (HGFs). MATERIAL AND METHODS: Sample discs from the 3D-printed resin material were printed (2 mm in height and 6 mm in diameter [N = 40]) and divided into 4 groups (n = 10) based on post-processing methods: a high-intensity UV polymerization device with isopropyl alcohol, a high-intensity UV polymerization device with a modified glycol solvent, a UV cleaning and curing unit with isopropyl alcohol, a UV cleaning and curing unit with a modified glycol solvent, and a control group cultured in DMEM medium. Different tests were performed to evaluate their cytocompatibility on HGFs: MTT assay, cell migration assay, cell cytoskeleton staining, scanning electron microscopy (SEM), and cell apoptosis and generation of intracellular reactive oxygen species (ROS). Statistical analyses were performed using one-way ANOVA and the Tukey post hoc test (? = 0.05). RESULTS: Cytocompatibility, MTT assay, cell migration assay, cell cytoskeleton staining, and SEM images were similar, regardless of the post-processing protocol, compared with the control group. CONCLUSIONS: No differences were found in the cytotoxicity of the 3D-printed resin material for occlusal devices after the following post-processing methods: two different UV-polymerization devices and two rinsing solvents (isopropyl alcohol and a modified glycol solvent).
dc.language.iso eng
dc.publisher WILEY
dc.rights http://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.rights.uri Atribución-NoComercial-SinDerivadas 3.0 España *
dc.title Influence of the post-processing protocol on a biocompatible 3D-printed resin
dc.type info:eu-repo/semantics/article
dc.identifier.pmid 39506359
dc.relation.publisherversion https://onlinelibrary.wiley.com/doi/10.1111/jopr.13980
dc.identifier.doi 10.1111/jopr.13980
dc.journal.title Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry
dc.identifier.essn 1532-849X


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta