| dc.contributor.author | Hernandis,Veronica | |
| dc.contributor.author | Escudero,Elisa | |
| dc.contributor.author | Pareja,Ana | |
| dc.contributor.author | Marin,Pedro | |
| dc.date.accessioned | 2025-10-20T14:40:38Z | |
| dc.date.available | 2025-10-20T14:40:38Z | |
| dc.date.issued | 2021-10 | |
| dc.identifier.citation | Hernandis V, Escudero E, Pareja A, Marín P. A fast, cost¿saving and sensitive method for determination of cefuroxime in plasma by HPLC with ultraviolet detection. Biomedical Chromatography. octubre de 2021;35(10):e5188. | |
| dc.identifier.issn | 0269-3879 | |
| dc.identifier.uri | https://sms.carm.es/ricsmur/handle/123456789/20506 | |
| dc.description.abstract | Cefuroxime (CFX) is a broad-spectrum second-generation cephalosporin and one of the best choices for antibiotic prophylaxis. However, when used in critically ill patients, it may present changes in its pharmacokinetic properties. Therefore, therapeutic drug monitoring of CFX is necessary for effective dosing strategies. A simple, rapid and sensitive liquid chromatographic method with UV detection was developed and validated for the quantification of CFX in plasma. The method involved a single-step precipitation of proteins with methanol and trifluoroacetic acid. Cefuroxime was analyzed on a Brisa (LCC18)-C-2 column in isocratic mode consisting of 0.1% trifluoroacetic acid in water and acetonitrile (75:25) with UV detection at a wavelength of 280 nm. The retention times of CFX and cephazolin (internal standard) were 9.8 and 7.4 min, respectively. The calibration curve was linear over a concentration range of 0.25-50 mu g/ml. The limits of detection and quantification were 0.1 mu g/ml and 0.25 mu g/ml, respectively. The accuracy and precision were always <10%. The mean recovery was 93.52%. This fast and simple method could be applied in routine analysis and pharmacokinetic studies. | |
| dc.language.iso | eng | |
| dc.publisher | WILEY | |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
| dc.subject.mesh | Cefuroxime/blood/chemistry/pharmacokinetics | |
| dc.subject.mesh | Chromatography, High Pressure Liquid/methods | |
| dc.subject.mesh | Drug Monitoring | |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Limit of Detection | |
| dc.subject.mesh | Linear Models | |
| dc.subject.mesh | Reproducibility of Results | |
| dc.subject.mesh | Spectrophotometry, Ultraviolet/methods | |
| dc.title | A fast, cost-saving and sensitive method for determination of cefuroxime in plasma by HPLC with ultraviolet detection | |
| dc.type | info:eu-repo/semantics/article | |
| dc.identifier.pmid | 34081795 | |
| dc.relation.publisherversion | https://dx.doi.org/10.1002/bmc.5188 | |
| dc.type.version | info:eu-repo/semantics/publishedVersion | |
| dc.identifier.doi | 10.1002/bmc.5188 | |
| dc.journal.title | Biomedical Chromatography | |
| dc.identifier.essn | 1099-0801 |